How to Calculate Pump Horsepower: Formula + Example
How much horsepower does your pump actually need? Before reaching for a motor catalog, start with the job the pump has to do. The flow, head and liquid properties determine the hydraulic load. Pump efficiency determines how much shaft power it takes to handle that load. Here’s how to calculate pump horsepower and use the result when evaluating an industrial pumping application.
What is the Pump Power Equation?
For liquid pumps using U.S. customary units, the pump horsepower formula is:
Pump shaft horsepower = (Q × H × SG) ÷ (3,960 × ηp)
Where:
- Q: Flow rate in U.S. gallons per minute (GPM)
- H: Total pump head in feet of the pumped liquid
- SG: Liquid specific gravity relative to water
- ηp: Pump efficiency expressed as a decimal
Use 0.75 for 75% efficiency. The constant 3,960 converts these units into horsepower. This equation estimates shaft input power, also called brake horsepower (BHP), at a specified operating point.
Hydraulic horsepower is the power delivered to the liquid:
Hydraulic horsepower = (Q × H × SG) ÷ 3,960
Dividing hydraulic horsepower by pump efficiency accounts for losses within the pump. The Hydraulic Institute’s pump power guidance explains this distinction and why electrical input requires an additional motor-efficiency calculation.
Get the Inputs Right Before Calculating Horsepower
Flow rate: Use the required process flow at the operating condition being evaluated. If demand changes, calculate more than one operating point.
Total dynamic head: Include elevation differences, pressure differences between the source and destination, and piping and equipment losses. Account for velocity differences where applicable. Discharge gauge pressure alone does not represent total pump head. DXP’s friction loss calculation guide explains the resistance created by piping, valves and fittings.
Specific gravity: Use the liquid density at operating temperature. Water near ambient temperature has an SG close to 1.0. Denser liquids require more hydraulic power at the same flow and head.
Pump efficiency: Obtain efficiency from the manufacturer’s curve at the specified flow, speed and impeller diameter. Avoid borrowing an efficiency value from another pump or assuming the best efficiency point applies throughout operation. Our guide to reading a centrifugal pump curve explains how these values fit together.
Pump Horsepower Calculation Example
Consider a centrifugal pump transferring water under these assumed conditions:
- Flow: 500 GPM
- Total dynamic head: 150 ft
- Specific gravity: 1.0
- Pump efficiency: 75%, or 0.75
First, calculate hydraulic horsepower:
Hydraulic horsepower = (500 × 150 × 1.0) ÷ 3,960 = 18.94 HP
Then account for pump efficiency:
Pump shaft horsepower = 18.94 ÷ 0.75 = 25.25 HP
The pump requires approximately 25.3 shaft horsepower at this operating point. That result already exceeds a 25 HP motor’s nominal output rating, before reviewing other operating conditions.
For a motor operating at an assumed 92% efficiency, with direct coupling and no drive losses included:
Electrical input = (25.25 × 0.746) ÷ 0.92 = 20.5 kW
Motor efficiency changes the electrical input required. It does not change the pump’s calculated shaft requirement. Include VFD or transmission losses separately when applicable.
Why Calculated Horsepower Does Not Finish Motor Selection
A pump power calculation describes one condition. Final motor selection must account for the permitted operating range, maximum liquid density, startup demands and applicable derating.
For centrifugal pumps, review the manufacturer’s power curve across expected flows. Power can rise as flow increases, depending on pump design. A motor that handles the design point may overload elsewhere on the curve.
Viscous liquids also require attention. Water-based curves may need corrections for flow, head and efficiency before estimating shaft power. Changing specific gravity alone does not account for viscosity.
A calculation provides an estimate of required horsepower. Performance testing checks how the pump actually performs by measuring flow, head and shaft power under specified conditions. DXP’s in-house testing facilities in Texas and Louisiana provide that verification before equipment goes into service.
Put Your Pump Calculation to Work with DXP
Have your flow and head figures ready? Bring us the liquid properties and operating conditions, too. DXP can help evaluate centrifugal pumps, electric motors and testing needs for your application.
Contact the pump experts at DXP to review your requirements today.